Design and Development of an Isothermal-Based Contrast Media Storage Device for Optimal Temperature Stability

Indonesian Journal of Public Health Sagita Yudha

Penulis / Author

1
Sagita Yudha (Universitas Baiturrahmah) Utama
2
Noviardi Prima Putra (Universitas Baiturrahmah)
3
Nerifa Dewilza (Universitas Baiturrahmah)

Detail Publikasi

Indonesian Journal of Public Health

Nawala Education

3

2

1-9

E-ISSN: 3048-1139

Abstrak

Contrast media are used in radiological diagnostic imaging to enhance the visibility of internal body structures. The storage of contrast media must adhere to temperature standards, specifically around 37°C, to maintain its quality. The use of inadequate storage equipment can lead to crystallization or a decrease in the function of the contrast medium. This research aims to design and build an automatic contrast media storage device, test its functionality, and evaluate its performance based on applicable storage standards. This research uses an exploratory approach. The designed tool is in the shape of a square box, made of plywood with an aluminum coating on the outside and leads on the inside. The main elements include an electric heater, a digital thermostat for temperature control, and LED lights for illumination. Function tests are conducted using a checklist assessment, while performance tests are evaluated based on ease of use, safety, and effectiveness. The results of the functional test demonstrate that every part of the apparatus, including the temperature controller and heating element, functions effectively to keep the contrast media temperature at 37°C. The equipment is safe, efficient, and easy to use, according to the performance test findings.A > 80% feasibility level was achieved in both experiments. The automatic contrast media storage device's design and construction were successful in preserving the contrast media's quality, boosting radiographers' productivity, and making it appropriate for use in medical facilities. However, in rooms with air conditioning, the device's effectiveness is subpar. To enhance the device's performance in different environmental circumstances, more development is required.

Dana Insentif

D.2 - Bahasa Inggris 2.5 JT

Rp 2.500.000

Dana Disetujui

Rp 2.500.000

Dicairkan

04 Nov 2026

Alur Proses

Klaim Diajukan

25 Jul 2026

Verifikasi Fakultas

25 Jul 2026

Verifikasi Rektorat

12 Oct 2026

Verifikasi Sekretaris

06 Aug 2026

Disetujui Ka LPPM

06 Aug 2026

Dana Dicairkan

04 Nov 2026
Status Saat Ini Selesai

Informasi Dosen

SY

Sagita Yudha

NIDN: 1009029301

Asisten Ahli

Fakultas Fakultas Vokasi
Prodi Radiologi
... online